Smart Modular Data Center · SMDC

The Smart Modular Data Center.

Planned, designed and built in Canada, 0 to 100.

A complete, pre-engineered data centre, power, cooling, NOC and servers in one container, monitored by ProDCIM and engineered as one system. Sovereign by default, and built on Canadian soil.

  • 0 → 100 build
  • Power · NOC · servers
  • Made in Canada
  • ProDCIM inside
Smart Modular Data Center isometric cutaway, full layout
SMDC, full layout

Why "smart"

Not a container with racks, a data centre that thinks.

A Smart Modular Data Center ships as one engineered system, instrumented end to end and live on the platform from day one.

Intelligent by default

ProDCIM and AI analytics are wired in at the factory. Every zone reports, and anomalies surface before they become outages.

Engineered as one

Power, cooling, NOC and servers are designed together as a single system, not assembled from mismatched parts on site.

Built & tested in Canada

Assembled and burn-in tested on a Canadian line, then shipped ready to run, not drop-shipped from overseas.

Sovereign & remote-first

Operated remotely, able to run fully offline, with your data kept on Canadian soil.

System architecture

Five subsystems, engineered as one.

Power, cooling, compute, monitoring and network are designed together, with ProDCIM watching every layer.

Power
Utility feed
ATS
MDP
UPS A / B
Battery A / B
Rack PDU
Cooling
Condenser
Chiller / DX
In-row CRAC
Hot / cold aisle
Compute
Server racks
Structured cabling
KVM / console
Monitoring
Sensors
DAQ node
ProDCIM
NOC
Network & security
Core switch
Secure VPN
RBAC
Access control

ProDCIM monitors every layer, from the utility feed to the rack

Power

A dual A/B path from the transfer switch to the rack PDU, with dual UPS and battery, N+1, metered at the bus bar.

  • ATS
  • UPS A/B
  • N+1
  • Bus-bar metered

Cooling

N+1 cooling sized to the IT load, air, in-row or liquid, with hot/cold-aisle containment built in.

  • N+1
  • Air / in-row / liquid
  • Containment

Compute

Pre-wired racks with A/B PDUs and structured cabling, with room for 40 to 100 kW per rack in the AI pod.

  • Pre-wired racks
  • A/B PDU
  • 40–100 kW

Monitoring

ProDCIM commissioned at the factory, every sensor and circuit reporting from day one across every layer.

  • ProDCIM
  • Temp · humidity · leak · smoke
  • Power · door

Network & security

Secure connectivity with role-based access, audit logging and physical access control.

  • Secure VPN
  • RBAC
  • Audit
  • Access control

Inside the build

Every zone, engineered and laid out.

From the cooling condenser to the last server rack, the whole data centre is designed as one continuous layout, before a single panel is cut.

SMDC full engineered layout, power, NOC and server zones
Full layout · power → NOC → servers
  • Cooling

    Condenser and N+1 cooling sized to the IT load, with hot/cold-aisle containment built in.

  • Power chain

    ATS, main and unit distribution, dual UPS and battery cabinets, an A/B redundant path metered end to end.

  • NOC

    An on-board monitoring station running ProDCIM, with a secure access door and full audit trail.

  • Server zone

    Pre-wired racks with PDUs and sensors, labelled, tested and ready for your IT load.

SMDC three-quarter view
Server & NOC view
SMDC side view
Power & cooling end
SMDC end elevation
End elevation

Engineering renders of the Prochista SMDC

From 0 to 100

How we build an SMDC, end to end.

One team owns the whole journey, from the first site survey to a live data centre, so the schedule has no surprises and the platform is live on day one.

  1. 0%

    1. Discover

    Site survey and assessment of power, space, access and environmental constraints.

    Site assessment
  2. 12%

    2. Size

    Confirm IT load, rack density, redundancy (N+1) and the right form factor for the site.

    Capacity & redundancy plan
  3. 25%

    3. Design

    Electrical, mechanical, cooling and rack layout engineered, with ProDCIM monitoring designed in.

    Engineering drawings
  4. 40%

    4. Procure

    Source components and long-lead items against the design, with a Canadian supply chain.

    Bill of materials
  5. 58%

    5. Fabricate

    Build the container or enclosure; install the power chain, cooling and containment on the line.

    Power & cooling installed
  6. 72%

    6. Integrate

    Mount and wire racks, sensors and PDUs; commission ProDCIM and label every point.

    ProDCIM commissioned
  7. 85%

    7. Test (FAT)

    Factory acceptance test and burn-in under load, with a documented sign-off.

    FAT report
  8. 94%

    8. Deliver & install

    Lift, truck or palletise to site; place on the pad and connect power and network.

    On site
  9. 100%

    9. Commission & go-live

    Final checks, handover and ProDCIM live, first packet in days, not quarters.

    Live + handover

Then: remote-first operations, support, parts and spares, backed by a Canadian team.

Canadian by design

Built in Canada, sovereign by design.

For a data centre that holds critical or regulated workloads, where the hardware is built and where the data lives both matter. Prochista keeps both in Canada.

Made in CanadaSOC 2 Type II auditedCanadian-built · SOC 2 Type II audited

Designed & assembled in Canada

Engineering, integration and burn-in done in-country, not drop-shipped from overseas.

Your data stays in Canada

Deployed on-prem or in a Canadian region, your data never has to leave the country.

Sovereign or air-gapped

Run fully offline for defense and critical infrastructure, with ProDCIM on-prem.

Canadian engineering & support

Built and backed by a Canadian team, with parts, spares and a real phone number.

Three form factors

One architecture inside, whatever the size.

Same subsystems, same dashboards, same runbooks, from a single edge rack to a high-density AI pod.

Container

20 / 40 ft drop-in

ISO-spec containers ready to lift onto a pad, power, cooling, fire-suppression and racks pre-wired.

  • ISO-spec
  • Pre-wired
Micro

Single-rack edge

Self-contained 42U enclosure with sealed cooling, monitoring and battery back-up, ships on a pallet.

  • 42U
  • Palletised
GPU pod

High-density AI

Liquid-cooled, high-density pods for training and inference, 40 to 100 kW per rack.

  • Liquid-cooled
  • 40–100 kW

Pre-engineered

Things you don't have to spec, source or wire.

Pre-wired sensors

Temperature, humidity, leak, smoke, door and rack-PDU sensors wired from the factory, labelled and tested.

ProDCIM-ready

Commissioned with the ProDCIM platform at the factory, plug in network, sign in, see live data.

Climate-controlled

N+1 cooling sized to the IT load, air, in-row or liquid, depending on density.

Hot / cold aisle

Containment built in, not bolted on, measured separation and predictable air flow.

Remote-first ops

Built to be operated remotely, every fault routes through ProDCIM, every action is auditable.

Rapid deployment

Containers land on a pad and run in days, micro modules unbox and go live the same week.

On the platform

ProDCIM live from day one.

Sample platform data shown.

prodcim.local · racks
ProDCIM rack view
prodcim.local · NOC dashboard
ProDCIM NOC dashboard

Part of the platform

A data centre that monitors itself.

Plan, design and build your SMDC, in Canada

Book a walkthrough and we'll scope a Smart Modular Data Center for your load, site and sovereignty needs, end to end.